10.94
1 NC/Drive Machine Data
1.11.1 611A drive machine data MSD (SW 3)
D e s i g n a t i o n
MD
No.
Standard
value
Maximum input
value
Reference
system
Input
unit
311
Current with I/F control
40.0
100.0
--
%
312
Frequency for I/F control
0
800.0
--
Hz
313
Activation I/F control
0
1
--
HEX
316
Display P gain current
controller
337
Creep speed angle
controller
300
600
--
rev/min
338
Hysteresis MD 337
25
256
--
rev/min
399
Data version
--
65535
--
--
© Siemens AG 1992 All Rights Reserved 6FC5197- AA60