10.94
1 NC/Drive Machine Data
1.11.1 611A drive machine data MSD (SW 3)
D e s i g n a t i o n
MD
No.
Standard
value
Maximum input
value
Reference
system
Input
unit
31
P-gain speed controller
Motor 1
32
120.0
--
--
32
Reset time speed controller
Motor 1
20
6000
--
ms
35
Smoothing time Motor 1
torque setpoint
3
1000
--
ms
36
Encoder phase error
compensation
0
+400
--
--
37
Switchover speed motor
encoder evaluation 1
32000
32000
--
rev/min
38
Hysteresis MD 37
50
500
--
rev/min
39
1st torque limiting value
Motor 1
100
180
--
%
40
Generative limitation
Motor 1
100
100
--
%
41
2nd torque limiting value
Motor 1
50
100
--
%
42
Switchover speed for MD 40
Motor 1
500
Motor max.
speed
--
rev/min
43
Hysteresis MD 42 Motor 1
20
Motor max.
speed
--
rev/min
44
Selection torque setpoint
smoothing
Motor 1 and 2
1
1
--
HEX
45
Cut-in speed torque setpoint
smoothing
Motor 1
4000
Motor max.
speed
--
rev/min
46
Hysteresis MD 45 Motor 1
50
Rated speed
--
rev/min
47
M
dx
for M
d
< M
dx
message
90
100
--
%
50
Switching speed from M
d1
to
M
d2
Motor 1
4 x motor
rated
speed
Motor max.
speed
--
rev/min
52
Transfer MD to FEPROM
0
1
--
HEX
53
Control word
0000
FFFF
--
HEX
© Siemens AG 1992 All Rights Reserved 6FC5197- AA60
1–53
SINUMERIK 840C (IA)
Summary of Contents for SIMODRIVE 611-D
Page 2: ......