1 NC/Drive Machine Data
08.96
1.4 Spindle-specific values (max. 6 spindles)
D e s i g n a t i o n
MD
No.
Standard
value
Maximum
input value
Reference
system
Input
unit
456* v: Traversing path variable
increment weighting
5625
65000
99999999
3)
--
--
458* f: Pulse multiplication
EXE/611D/HMS
0
128
512
--
units (MS)
459* Zero mark offset
0
±99999999
18 000
4)
--
0.01 degrees
460* Setpoint output
2)
3)
4)
0
0
0
05 12 00 00
15 00 10 00
30 00 10 10
ANALOG
DIGITAL
DIGITAL
--
--
4600
2-3
Setpoint on digital drive
3)
0
--
--
4600
4-5
SPC/HMS setpoint output
3)
0
12
--
--
4600
6-7
Drive/servo loop
module No.
3)
0
30
4)
--
--
461* Assigned C axis
0
30
--
--
462* Cut-off frequency of spindle
encoder
200
16000
--
kHz
465* Feedforward factor
0
1000
--
0.1 %
466* Position controller clock
spindle
1
64
--
Multiple of position
controller's basic
clock frequency
467* Time constant for feedforward
control
0
9999
1000
4)
--
0.1 ms
468* Normalization max. set
2)
rev/min
3)
10000
10000
9000
4)
32000
20000
32000
4)
--
--
mV
,
0.01 % of
max. motor
speed
469* Factor for gain changeover
100
16000
--
%
478* Acceleration time constant with
position controller
Gear stage 1
2000
50000
--
1 ms
479*
- // -
Gear stage 2
2000
50000
--
1 ms
480*
- // -
Gear stage 3
2000
50000
--
1 ms
481*
- // -
Gear stage 4
2000
50000
--
1 ms
482*
- // -
Gear stage 5
2000
50000
--
1 ms
483*
- // -
Gear stage 6
2000
50000
--
1 ms
_______
1)
If MD 520* bit 3=1, input resolution is 0.1 rev/min
2)
Up to SW 2
3)
SW 3 and higher
4)
SW 5 and higher