1 NC/Drive Machine Data
10.94
1.11.1 611A drive machine data MSD (SW 3)
D e s i g n a t i o n
MD
No.
Standard
value
Maximum input
value
Reference
system
Input
unit
63
Max. motor temperature
Motor 1
Depends
on motor
170
--
°C
64
Fixed temperature
0
170
--
°C
65
Timer
motor temperature alarm
240
600
--
sec.
72
Address DAC 2
3048
0FFFF
--
HEX
73
Shift factor DAC 2
0
15
--
--
74
Offset DAC 2
0
7F
--
HEX
76
Address DAC 1
3044
0FFFF
--
HEX
77
Shift factor DAC 1
0
15
--
--
80
Offset DAC 1
0
7F
--
HEX
95
Power section code number
7
12
--
--
96
Motor code number
Motor 1
101
332
--
--
97
Boot
0
2
--
HEX
98
No. of encoder marks motor
meas. system
2048
4096
--
--
99
Firmware version
--
99.99
--
--
103
Frequency torque setpoint
filter
Motor 1
300
450
--
Hz
104
Grading torque setpoint filter
Motor 1
1.00
10.00
--
--
116
Correction P gain
Current controller
0
255
--
--
117
Selection torque setpoint filter
Motor 1
0
1
--
HEX
1–54
© Siemens AG 1992 All Rights Reserved 6FC5197- AA60