09.95
1 NC/Drive Machine Data
1.11.2 611D drive machine data MSD (SW 3)
D e s i g n a t i o n
MD
No.
Standard
value
Maximum input
value
Reference
system
Input
unit
1502 Time constant speed setpoint
filter
0
500
--
ms
1600 Concealable POWER ON
611-D alarms
0000
FFFF
--
HEX
1601 Concealable reset
611-D alarms
0000
FFFF
--
HEX
1602 Warning threshhold motor
temperature
120
200
--
°C
1603 Timer motor temperature
alarm
240
600
--
s
1604 DC link undervoltage warning
threshold
200
600
--
V
1605 Timer speed controller at stop
200.0
10000.0
--
ms
1700 Status of binary inputs
0000
7FFF
--
Hex
1701 DC link voltage
0
32 767
--
V
1702 Motor temperature
0
32 767
--
°C
1706 Speed setpoint
0.0
32 767
--
rev/min
1707 Speed actual value
0.0
32 767
--
rev/min
1708 Smoothed current actual value
0.0
32 767
--
%
1710 Significance current
representation
0.0
32 767
--
µ
A
1711 Significance speed
representation
0.0
32 767
--
rev/min
1720 CRC diagnosis parameter
0000
FFFF
--
HEX
1797 Data version
0
32 767
--
--
1798 Firmware date
0
32 767
--
--
1799 Firmware version
0
32 767
--
--
© Siemens AG 1992 All Rights Reserved 6FC5197- AA60
1–65
SINUMERIK 840C (IA)
Summary of Contents for SIMODRIVE 611-D