background image

INSTRUCTIONS FOR:

GALVANIZED STEEL SHED

 

GREEN

1.5 x 0.8 x 1.9m

MODEL NO: 

GSS1508G 

 

WARNING!

 Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when building this shed.

 

Keep the work area clean, uncluttered and ensure there is adequate lighting.

 

Keep children and unauthorised persons away from the working area.

 

DO NOT

 use the shed for any purpose other than that for which it is designed.

 

Use appropriate safety clothing including eye protection.

  

NOTE: 

The assembly of this product will require assistance.

 

DO NOT 

attempt assembly in windy conditions 

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE 

PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL 

INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, 

and properly maintained, give you years of trouble free performance.

 1.  SAFETY

2. INTRODUCTION

3. SPECIFICATION

4.  CONCRETE SLAB

Galvanized, steel panels easily assembled to form a rigid and secure shed. Has skillion (sloping) roofs and single doors. Doors are secured by 

cross bolt and eyelet which will accept a padlock (not included) for additional security. All models are supplied with bolt-down fixing kits. 

 

Model No:

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

GSS1508G 

 

Overall Size (W x D X H*):

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1500 x 800 x 1900mm

 

Roof Type:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Skillion

 

*Minimum Wall Height.

Concrete slab: Ensure that your site is level. It is recommended that your slab is 100mm thick and you use builders plastic and F52 reinforcing 

mesh. We recommend that you make your slab 100mm bigger than the base dimensions of your shed. This will allow for a 50mm edge around your 

shed. We recommend that you slope the 50mm edges downward by 10 mm so that rain water can be drained away from your shed.

Original Language Version

 © Jack Sealey Limited

GSS1508G      Issue: 1 - 28/08/14

Summary of Contents for GSS1508G

Page 1: ...SE Thank you for purchasing a Sealey product Manufactured to a high standard this product will if used according to these instructions and properly maintained give you years of trouble free performance 1 SAFETY 2 INTRODUCTION 3 SPECIFICATION 4 CONCRETE SLAB Galvanized steel panels easily assembled to form a rigid and secure shed Has skillion sloping roofs and single doors Doors are secured by cros...

Page 2: ... QTY Check Sheet Sheet 1980x770 left rear wall 1L 1 Sheet Sheet 1980x770 right rear wall 1R 1 Sheet Sheet 1900 1980x770 left side wall 2L 1 Sheet Sheet 1900 1980x770 right side wall 2R 1 Original Language Version Jack Sealey Limited GSS1508G Issue 1 28 08 14 Sheet Sheet 855x770 roof 3 2 Sheet 1900x708 front 4 1 Door Sheet 1845x770 door 5R 1 6 CONTENTS 5 TOOLS REQUIRED ...

Page 3: ... Jamb jamb 1898 front 41A 1 Jamb jamb 1898 front 41B 1 Jamb jamb 775 front 42 1 Lip lip 856 roof 50 2 FITTINGS PACK Picture Component QTY Picture Component QTY Self tapping screws 10mm 120 Self tapping screws 16mm 10 4 10mm Rivet 12 3 10mm Rivet 6 Pad bolt 1 Keeper 1 Bracket 8 M8 18m m Hexagonal bolt 8 M8 Hexagonal Nut 8 Mid wall brace bracket 3 Self tapper safety cover 25 Channel safety cover L t...

Page 4: ...ble your shed using saw horses with timber battens attached the timber needs to be the same length as the shed 1 5m Alternatively a trestle table can be used Original Language Version Jack Sealey Limited GSS1508G Issue 1 28 08 14 7 PARTS DIAGRAM ...

Page 5: ...ram Now fit 20B top channel and 20C bottom channel to the sheeting by tapping it in diagram A or sliding it in diagram B Note that the small lip of the channel is always facing out This is to ensure that rain water can not build up inside the shed Original Language Version Jack Sealey Limited GSS1508G Issue 1 28 08 14 ...

Page 6: ...r slide in 21A top channel and 21B bottom channel Fix and position the 32 mid wall channel by the self tapping screws Fix 21B the bottom channel by the self tapping screws but NOT 21A the top channel in this stage Note that the small lip of the channel is always facing out This is to ensure that rain water can not build up inside your shed Repeat the same steps for 2L the other side wall Original ...

Page 7: ...per the diagram 8 3 2 Now tap or slide in 20A and 20A the channels to the sheeting and fix them using the self tapping screws 8 3 3 Now tap or slide in 20A and 20A the channels to the sheeting and fix them using the self tapping screws Original Language Version Jack Sealey Limited GSS1508G Issue 1 28 08 14 ...

Page 8: ...he mid wall channel to the sheeting and fix them using the self tapping screws NOT those with cross mark in this stage 8 4 2 Fit the 41A the jamb 42 the jamb and 23 the bottom channel and fix them using the self tapping screws NOT those with cross mark in this stage Be aware of the joint details per the diagrams DIAGRAM B IS AS THE SAME AS DIAGRAM A Original Language Version Jack Sealey Limited GS...

Page 9: ...nel per the diagram Use riveter to fix the door into the pre drilled holes Fix the pad bolt but NOT its keeper in this stage to the pre drilled holes using supplied rivets or self tapping screws Original Language Version Jack Sealey Limited GSS1508G Issue 1 28 08 14 ...

Page 10: ...wall panel per the diagram Use riveter to fix the door into the pre drilled holes Fix the pad bolt but NOT its keeper in this stage to the pre drilled holes using supplied rivets or self tapping screws Original Language Version Jack Sealey Limited GSS1508G Issue 1 28 08 14 ...

Page 11: ...ng the supplied masonry bolts as per the diagram Strengthen your mid wall brace by applying 72 the mid wall brace bracket on each corner if necessary MASONRY BOLT Original Language Version Jack Sealey Limited GSS1508G Issue 1 28 08 14 ...

Page 12: ... sealant to help seal around all joins and wherever you feel that water may get in under these extreme conditions Shed is not to be used to store corrosive substances or as a chemical store Apply channel safety cover L type on channel 32 and R type on channel 33R Apply the self tapper covers on the screws fixed on the wall to prevent accidental injuries Original Language Version Jack Sealey Limite...

Page 13: ...cording to local regulations NOTE It is our policy to continually improve products and as such we reserve the right to alter data specifications and component parts without prior notice IMPORTANT No liability is accepted for incorrect use of this product WARRANTY Guarantee is 12 months from purchase date proof of which will be required for any claim INFORMATION For a copy of our latest catalogue a...

Reviews: