Vaxcel T0454 Assembly And Installation Instructions Download Page 1

ASSEMBLY  AND  INSTALLATION 

                INSTRUCTIONS

181029

1. Install a bulb (not included). See relamping label 

    at socket area or packaging for maximum allowed

    wattage.

2. Pull out the wires and grounding wire from the post. 

    Make wire connections using the wire connectors 

(B)

:

    ---The hot wire (usually balck  insulation) from the 

        fixture to the black wire from the post.

    ---The neutral wire (usually white insulation) from 

        the fixture to the white wire from the post.

    ---The grounding wire (usually green insulation or 

        bare wire from the fixture to the grounding wire 

        from the post.

    Carefully put the wires back into the post.

3. Place the fitter on the top of the post, and then 

    secure it with fitter screws.

    NOTE: With silicone caulking compound, 

    caulk completely around where the fitter 

    meets with the post surface to prevent water

    from seeping into the post.

4. Attach the glass onto the glass holder, secure it 

    with four replacement ball nuts.

Bulb Type A Max.60W

       (not included)

Glass

NOTES: 1. Before installing, consult local electrical codes for wiring and grounding requirements.

               2. READ AND SAVE THESE INSTRUCTIONS.

T0454

Hardware Package (included):

Fitter Screw (A)

Wire Connector (B)

Turn off the power at fuse or circuit box

Installation Steps

WARNING:

TO AVOID RISK OF ELECTRICAL SHOCK, BE SURE TO SHUT OFF

POWER BEFORE INSTALLING OR SERVICING THIS FIXTURE.

Turn on the power at fuse or circuit box

Post Grounding Wire

Fixture Wire

Wire Connector (B)

Post

Fitter

Fixture Grounding Wire

Fitter Screw (A)

Glass Holder

Replacement Ball Nut 