Ports on the video matrix
91
Siemens Building Technologies
Fire Safety & Security Products
06.2008
15.1.4 Remote set-up ’COM2
ÅÆ
MODEM’
A modem for remote set-up can be connected to the COM2 interface on the
SIMATRIX (activate the COM2 box on the
Messages/ keyboard
index card). A
special program is required for remote set-up.
15.1.5 Repeating
messages (COM2, 3, 4)
These settings relate to chapter 15.1.1. It is possible to work with or without a hard-
copy print-out:
z
Message transmission without repetition
No hard-copy print-out
(Set using the arrow keys)
z
Message repetition after x seconds
With hard-copy print-out
(Use the arrow keys to set the number of seconds)
The first entry applies to COM2
The second entry applies to COM3
The third entry applies to COM4
15.1.6 Keyboard on COM2, COM3, COM4
The SUT 48 and CKAxx10 keyboards can be connected directly to COM2, COM3
or COM4 (in contrast to other keyboards).
Enter here whether, and to which interface, the keyboard is connected.
z
No keyboard connected to COMx
(Set using the arrow keys)
z
Keyboard with address: x connected to COMx
(Set address x using the arrow keys)
In order to refresh the OSD on the monitor allocated to the SUT 48, it is necessary to permanently
allocate the keyboard address. "Normal" keyboards can also be connected in addition to this
permanent allocation.
For example: 3 Keyboards: 1x SUT 48 and 2 x VMT32
S-I/O 1 is left free, SUT 48 on address 1, one permanently allocated keyboard. Upper address 3.
Both the other keyboards can be connected at will from S-I/O 2 onward.
If connection has been made via a serial interface (COM2 to COM4), the SUT 48 display is not active
as no data transfer will take place between the video matrix and the keyboard.