Basic alarm parameters
70
Siemens Building Technologies
Fire Safety & Security Products
06.2008
10
Basic alarm parameters
This dialogue screen allows basic alarm processing parameters to be set in the
system. These include, for example:
z
Number and connection of alarm lines
The following data is important as otherwise alarms will either not be recognised or not correctly
recognised.
z
Alarm zone alarm enabling at preset times.
Firstly, you must indicate to which alarm line input on the SIMATRIX you have
connected your first alarm line, and secondly how many alarm lines are used.
These alarm lines will then be correctly allocated if you have connected them in
sequence from first to last to the alarm line inputs on the SIMATRIX, starting with
the first input for alarm lines (setting for 1st alarm line at.. ). The
Alarm
line/camera groups
dialogue screen allows the setting of further parameters for
each individual alarm line.
Operating
profile
Alarm inputs on the
basic unit
Alarm inputs on the
extension unit
Alarm inputs on
alarm box 1
Alarm inputs
on alarm box 2
Operating
profile 1
1 – 32
33 – 64
65 – 192
193 – 240
Operating
profile 2
1 – 32
none
33 – 160
161 – 240
Operating
profile 3
none
none
1 – 128
129 – 240
Fig. 52
Basic alarm parameters for SIMATRIX NEO