Ports on the video matrix
89
Siemens Building Technologies
Fire Safety & Security Products
06.2008
The table below describes connectable devices and their interface settings:
Connection from
SIMATRIX
SYS/NEO/648 to
Interface
COM2/ COM3/ COM4
Baud rate
2400/ 9600/
19200 Baud
Bit code
6/ 7/ 8
Parity
E= even
0= odd
N= none
Stop bits
1/ 1.5/ 2
Main matrix
COM2/ COM3/ COM4
19200
8
E
2
Sub-station COM2/
COM3/
COM4 19200
8
E
2
TELEMAT
COM4
9600/19200
8
E
2
TELEMAT
parameterisation
COM2 19200
8
E
2
SISTORE-NT
switch-over control
COM2/ COM3/ COM4
19200
8
E
2
SISTORE-NT
operation
COM2/ COM3/ COM4
19200
8
E
2
LMS COM3
2400 8
N 1
GMA COM3
9600 7
E 1
External computer
COM2/ COM3/ COM4
19200
8
E
2
IVM NT (RS485)
COM2/ COM3/ COM4
19200
8
E
2
IVM NT (RS 232)
COM2
19200
8
E
2
SIPORT COM3
9600
7 E
1
Connection from
SIMATRIX 164 to
Interface
COM2
Baud rate
2400/ 9600/
19200 Baud
Bit code
6/ 7/ 8
Parity
E= even
0= odd
N= none
Stop bits
1/ 1.5/ 2
LMS COM2
9600 8
N 1
IVM NT (RS 232)
COM2
19200
8
E
2
IVM NT (RS 485)
COM2
19200
8
E
2