Programming keyboards
48
Siemens Building Technologies
Fire Safety & Security Products
06.2008
3.
You can permanently allocate the alarm reset function to an output so that
pressing the appropriate key will always delete the alarm image switched to
this output.
(Scroll bar set to the desired output number)
Alarm line active
This function activates an alarm line in a similar way to the ‘Alarm line/camera
group’ dialogue screen.
Changing alarm status can be protected by an access code (see section 13.3).
1.
Enter the alarm line number using the digit keys and press this function key.
The key has the following special functions when operated in conjunction with the
digit sequences below:
255:
all
alarm lines are switched to
active
254:
deletes access rights for changing alarm line status
253:
switches between summer and winter time (also known as toggling)
The key is also used to enter the access code referred to above (see section 13.4)
Alarm line inactive
This function deactivates an alarm line in a similar way to the ‘Alarm line /camera
group’ dialogue screen.
Alarm line deactivation remains in force until the next system reset.
Alarm handling can be protected by an access code (see section 13.3).
1.
Enter the alarm line number using the digit keys and press this function key.
The key has the following special functions when operated in conjunction with the
digit sequences below:
255:
all
alarm lines are switched to
inactive
254:
deletes access rights for changing alarm line status
253:
switches between summer and winter time (also known as toggling)
The key is also used to enter the access code referred to above.
Alarm zone active / inactive
Each press of the function key switches between the active /inactive condition.
z
Alarm zone 1...8:
This allows a complete alarm zone to be switched to active/inactive. It applies to
alarm lines in the corresponding alarm zone.
z
every:
The ‘every’ setting is effective for the alarm zone that has been selected using
the digit keys.