Technical specifications
8.10 SFP technical specifications
SCALANCE X-300
216
Operating Instructions, 05/2016, A5E01113043-20
Device:
Transceiver
(Variant)
Modular installation options:
Media module installation in slot
SFP installation in SFP media module
SFP992-1
(1 x 1000 Mbps, LC port
optical, multimode glass,
up to max. 750m)
-
●
SFP992-1LD
(1 x 1000 Mbps, LC port
optical, single mode glass,
up to max. 10km)
-
●
SFP992-1LH
(1 x 1000 Mbps, LC port
optical, single mode glass,
up to max. 40km)
-
●
SFP992-LH+
(1 x 1000 Mbps, LC port
optical, single mode glass,
up to max. 70km)
-
●
SFP992-1ELH
(1 x 1000 Mbps, LC port
optical, single mode glass,
up to max. 120km)
-
●
*) Note: When used in shipbuilding, installation on a 35 mm DIN rail is not permitted. In ships, the 35 mm DIN rail does not provide ade-
quate support.
Table 8- 135 Permitted ambient conditions
Device:
transceiver
(Variant)
Operating tem-
perature
Storage/transport
temperature
Relative humidity
at 25 °C during
operation, maxi-
mum
Operating alti-
tude at max. xx
°C ambient
temperature
SFP991-1
(1 x 100 Mbps, LC port
optical, multimode glass, up
to max. 3 km)
-40 °C through
+85 °C
-40 °C to +85 °C <= 95%
(no condensa-
tion)
2000 m at max.
56 °C
3000 m at max.
50 °C
SFP991-1LD
(1 x 100 Mbps, LC port
optical, single mode glass,
up to max. 26 km)
-40 °C through
+85 °C
-40 °C to +85 °C <= 95%
(no condensa-
tion)
2000 m at max.
56 °C
3000 m at max.
50 °C
SFP991-1LH+
(1 x 100 Mbps, LC port
optical, single mode glass,
up to max. 70km)
-40 °C through
+85 °C
-40 °C to +85 °C <= 95%
(no condensa-
tion)
2000 m at max.
56 °C
3000 m at max.
50 °C
SFP992-1
(1 x 1000 Mbps, LC port
optical, multimode glass, up
to max. 750m)
-40 °C through
+85 °C
-40 °C to +85 °C <= 95%
(no condensa-
tion)
2000 m at max.
56 °C
3000 m at max.
50 °C
SFP992-1LD
(1 x 1000 Mbps, LC port
optical, single mode glass,
up to max. 10km)
-40 °C through
+85 °C
-40 °C to +85 °C <= 95%
(no condensa-
tion)
2000 m at max.
56 °C
3000 m at max.
50 °C
SFP992-1LH
(1 x 1000 Mbps, LC port
optical, single mode glass,
up to max. 40km)
-40 °C through
+85 °C
-40 °C to +85 °C <= 95%
(no condensa-
tion)
2000 m at max.
56 °C
3000 m at max.
50 °C