Technical specifications
8.2 X-300 technical specifications
SCALANCE X-300
158
Operating Instructions, 05/2016, A5E01113043-20
Table 8- 3
Permitted ambient conditions
Device variant
Storage/transport tem-
perature
Operating temperature
Max. relative hu-
midity in operation
at 25 °C
Max. ambient tempera-
ture at operating altitude
X304-2FE,
X306-1LD FE,
X320-1FE,
X320-3LD FE
-40 °C to +70 °C
As of hardware product
version 1:
-40 °C to +60 °C
<= 95% (no con-
densation)
Max. 55 ℃ as of 2000 m
Max. 50 ℃ as of 3000 m
X307-3,
X308-2
-40 °C to +70 °C
For hardware product
version 1:
0 °C to +60 °C
As of hardware product
version 2:
-
10 ℃ to +60 °C
<= 95% (no con-
densation)
Max. 55 ℃ as of 2000 m
Max. 50 ℃ as of 3000 m
X307-3LD,
X308-2LD,
X308-2LH,
X308-2LH+,
X310,
X310FE
-40 °C to +70 °C
For hardware product
version 1:
0 °C to +60 °C
As of hardware product
version 2:
-
40 ℃ to +60 °C
<= 95% (no con-
densation)
Max. 55 ℃ as of 2000 m
Max. 50 ℃ as of 3000 m
8.2.2
Connectors and electrical data
Table 8- 4
Connection for end devices or network components
Device variant Electrical
over twisted pair
Optical
over fiber-optic cable
X304-2FE
4 x RJ-45 jacks with MDI-X assignment
10/100 Mbps (half / full duplex)
2 x SC duplex socket (MM)
(100 Mbps, full duplex to
100BaseFX)
X306-1LD FE
6 x RJ-45 jacks with MDI-X assignment
10/100 Mbps (half / full duplex)
1 x SC duplex socket (SM)
(100 Mbps, full duplex to
100BaseFX)
X307-3
7 x RJ-45 jacks with MDI-X assignment
10/100 Mbps (half / full duplex)
3 x SC duplex sockets
(1000 Mbps, full duplex to
1000BaseSX)
X307-3LD
7 x RJ-45 jacks with MDI-X assignment
10/100 Mbps (half / full duplex)
3 x SC duplex sockets
(1000 Mbps, full duplex to
1000BaseLX)
X308-2
7 x RJ-45 jacks with MDI-X assignment
10/100 Mbps (half / full duplex)
1 x RJ-45 socket with MDI-X pinning
10/100/1000 Mbps (half/ full duplex)
2 x SC duplex sockets
(1000 Mbps, full duplex to
1000BaseSX)
X308-2LD
7 x RJ-45 jacks with MDI-X assignment
10/100 Mbps (half / full duplex)
1 x RJ-45 jacks with MDI-X assignment
10/100/1000 Mbps (half / full duplex)
2 x SC duplex sockets
(1000 Mbps, full duplex to
1000BaseLX)