Approvals, certificates, standards
9.3 Product group XR-300M
SCALANCE X-300
Operating Instructions, 05/2016, A5E01113043-20
235
9.2.6
X-300M mechanical stability (in operation)
Device:
SCALANCE
(Variant)
IEC 60068-2-6 vibration
IEC 60068-2-27 shock
5 – 9 Hz: 3.5 mm
9 – 150 Hz: 1 g
1 octave/min, 20 sweeps
15 g, 11 ms duration
6 shocks per axis
X308-2M
(-)
●
●
X308-2M TS
(-)
●
●
9.3
Product group XR-300M
9.3.1
XR-300M approvals, certificates
Approvals issued
Note
Issued approvals on the type plate of the device
The specified approvals apply only when the corresponding mark is printed on the product.
You can check which of the following approvals have been granted for your product by the
markings on the type plate.
EC directives
SIMATIC NET products meet the requirements and aims of the following EC directives.
EMC directive (electromagnetic compatibility)
The SIMATIC NET products described in these operating instructions meet the requirements
of EC directive 2004/108/EC "Electromagnetic Compatibility" for the following areas of
application:
Field of application
Requirements
Emission
Immunity to interference
Industry
EN 61000-6-4 : 2007
EN 61000-6-2 : 2005