Adaptive Radio Management
21.2 Configuring ARM Features on an AP
SCALANCE W1750D UI
346
Configuration Manual, 02/2018, C79000-G8976-C451-02
In the SCALANCE W UI
To configure band steering:
1.
For client match configuration, specify the following parameters in the RF > ARM > Show
advanced options tab:
Parameter
Description
Client match Select Enabled to enable the Client match feature on APs. When enabled, client
count will be balanced among all the channels in the same band. For more infor-
mation, see ARM Overview on page 251. By default, the client match feature is
disabled.
NOTE: When client match is enabled, ensure that Scanning is enabled.
CM calcula-
ting interval
Specify a value for calculating the interval of Client match. The value specified for
CM calculating interval determines the interval at which client match is calculated.
The interval is specified in seconds and the default value is 30 seconds. You can
specify a value within the range of 10–600.
CM neighbor
matching %
Specify a value for CM neighbor matching %. This number takes into account the
least similarity percentage to be considered as in the same virtual RF neighbor-
hood of client match. You can specify a percentage value within the range of 20–
100. The default value is 75%.
CM threshold Specify a value for CM threshold. This number takes acceptance client count
difference among all the channels of client match into account. When the client
load on an AP reaches or exceeds the threshold, client match is enabled on that
AP.
You can specify a value within range of 1–255. The default value is 2.
SLB mode
Select a mode from the SLB mode drop-down list. The SLB mode determines the
balancing strategy for client match. The following options are available:
•
Channel
•
Radio
•
C Radio
2.
Click OK.
In the CLI
(scalance)(config)# arm
(scalance)(ARM)# client-match calc-interval <seconds>
(scalance)(ARM)# client-match calc-threshold <threshold>
(scalance)(ARM)# client-match nb-matching <percentage>
(scalance)(ARM)# client-match slb-mode 1
(scalance)(ARM)# end (scalance)# commit apply