Functions specific to SCALANCE
3.3 Digital input/output
SCALANCE S615 Command Line Interface
94
Configuration Manual, 06/2015, C79000-G8976-C406-02
3.3
Digital input/output
Introduction
The SCALANCE S device has a digital input/output. The connection is made using two 2-pin
terminal blocks. You will find information about the pin assignment in the operating
instructions of the device.
With CLI commands, you can open or close the digital output.
Application examples
●
Digital input to signal one item of information, for example "door open", "door closed"
●
Digital output, for example for "go to sleep" for devices on an automated guided transport
system.
3.3.1
show digital input
Description
This command shows the current setting of the digital input.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
or
cli#
Syntax
Call the command without parameters:
show digital output
Result
The current setting of the digital input is displayed.