Functions specific to SCALANCE
3.5 SINEMA RC
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
109
3.5
SINEMA RC
3.5.1
Introduction to the SRC section
This section describes commands for access to the SINEMA RC Server. You will find further
information on this in the Operating Instructions of the SINEMA RC Server.
3.5.2
show sinemarc
Note
This command is only available with a KEY-PLUG.
Description
This command shows information on SINEMA RC.
Requirement
You are in the Privileged EXEC mode.
The command prompt is as follows:
cli#
Syntax
Call the command without parameters:
show sinemarc
Result
The information is displayed.
3.5.3
Commands in the global configuration mode
This section describes commands that you can call up in the Global configuration mode.
In Privileged EXEC mode, enter the
configure terminal
command to change to this mode.
Commands relating to other topics that can be called in the Global configuration mode can
be found in the relevant sections.