![Siemens SCALANCE S615 Configuration Manual Download Page 52](http://html.mh-extra.com/html/siemens/scalance-s615/scalance-s615_configuration-manual_377351052.webp)
Configuration
2.1 System
SCALANCE S615 Command Line Interface
52
Configuration Manual, 06/2015, C79000-G8976-C406-02
2.1.9.2
coordinates latitude
Description
With this command, you enter a latitude coordinate.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
coordinates latitude <latitude>
The parameter has the following meaning:
Parameter
Description
Range of values / note
latitude
Input box for the latitude coordinate
max. 32 characters
To use spaces in the entry, enter
the latitude coordinate in quotes:
coordinates latitude "123
456"
Result
The latitude coordinate is created.
2.1.9.3
coordinates longitude
Description
With this command, you enter a longitude coordinate.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
coordinates longitude <longitude>