![Siemens SCALANCE S615 Configuration Manual Download Page 123](http://html.mh-extra.com/html/siemens/scalance-s615/scalance-s615_configuration-manual_377351123.webp)
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
123
System time
4
This part contains the sections describing how the system time is obtained and the settings.
4.1
System time setting
This section describes commands relevant for the configuration of the system time.
4.1.1
show time
Description
This command shows the settings of the system clock.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
or
cli#
Syntax
Call the command without parameters:
show time
Result
The settings for the system clock are displayed.
4.1.2
Commands in the global configuration mode
This section describes commands that you can call up in the Global configuration mode.
In Privileged EXEC mode, enter the
configure terminal
command to change to this mode.
Commands relating to other topics that can be called in the Global configuration mode can
be found in the relevant sections.
You exit the Global configuration mode with the
end
or
exit
command and are then in the
Privileged EXEC mode again.