![Siemens SCALANCE S615 Configuration Manual Download Page 431](http://html.mh-extra.com/html/siemens/scalance-s615/scalance-s615_configuration-manual_377351431.webp)
Diagnostics
10.1 Event and fault handling
SCALANCE S615 Command Line Interface
Configuration Manual, 06/2015, C79000-G8976-C406-02
431
10.1.10.8
severity
Description
With this command, you configure the threshold values for the sending of system event
notifications.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli (config-events) #
Syntax
Call up the command with the following parameters:
severity { mail | log | syslog } { info | warning | critical }
The parameters have the following meaning:
Parameter
Description
Range of values / note
Specifies the threshold value for send-
ing system event messages by e-mail.
-
log
Specifies the threshold value for enter-
ing system event messages in the log
table.
-
syslog
Specifies the threshold value for enter-
ing system event messages in the
Syslog file.
-
info
System events are processed as of the
severity level "
Information
".
-
warning
System events are processed as of the
severity level "
Warning
".
-
critical
System events are processed as of the
severity level "
Critical
".
-
Result
The settings for sending system event messages are configured.
The "severity" function is enabled.
Further notes
You disable the setting with the
no severity
command.
You display the status of this function and other information
show events severity