![Siemens SCALANCE S615 Configuration Manual Download Page 120](http://html.mh-extra.com/html/siemens/scalance-s615/scalance-s615_configuration-manual_377351120.webp)
Functions specific to SCALANCE
3.5 SINEMA RC
SCALANCE S615 Command Line Interface
120
Configuration Manual, 06/2015, C79000-G8976-C406-02
3.5.4.10
no shutdown
Note
This command is only available with a KEY-PLUG.
Description
With this command, you establish a connection to the configured SINEMA RC Server.
Requirement
You are in the SINEMARC configuration mode.
The command prompt is as follows:
cli(config-sinemarc)#
Syntax
Call the command without parameter assignment:
no shutdown
Result
The connection is enabled.
Further notes
You disable the connection with the
shutdown
command.
You display this setting and other information with the
show sinemarc
command.