Chapter 6
CPE Management Interface
RUGGEDCOM WiN5100/WiN5200
User Guide
56
Downloading CPE Software
Field
Description
Values: Primary | Secondary
Current SW Location
Displays the number of the memory bank from which the CPE software is running.
Values: 1 | 2
Primary SW Version
Displays the version number of the software in the Primary memory bank.
Primary SW Location
Displays the number of the current Primary memory bank.
Values: 1 | 2
Primary CDC
Displays the filename of the CDC (Customer Defaults Configuration) file in the Primary
memory bank.
Primary UV
Displays the filename of the UV (Unique Value) file in the Primary memory bank.
Secondary SW Version
Displays the version number of the software in the Secondary memory bank.
Secondary SW Location
Displays the number of the memory bank selected as the Secondary memory bank.
Secondary CDC
Displays the filename of the CDC (Customer Defaults Configuration) file in the
Secondary memory bank.
Secondary UV
Displays the filename of the UV (Unique Value) configuration file in the Primary memory
bank.
Configuration Changes Counter
Displays the number of changes made to configuration values on the CPE. This value
only includes changes to configuration values. It does not include events, such as
setting the primary software image or uploading a file.
4. The following operations can be performed from this pane:
•
Run Secondary
— Reboot the CPE and run the “Secondary” software image. Reboot a second time to
run the CPE using the “Primary” software image.
•
Set as Primary
— Set the current running software as the “Primary” image. For example, if the CPE is
running from the “Secondary” image, the “Primary” and “Secondary” designations are exchanged.
•
Reboot
— Reboot the CPE and run the “Primary” image.
Section 6.2.8.3
Downloading CPE Software
Use the
SW Download
pane to download CPE software from your FTP server. The CPE downloads all software
to the “Secondary” memory bank.
Procedure: Downloading software
1. Click the
Management
button. The
Current Status
pane appears.
2. In the options pane, click the
SW Upgrade
link, and then click the
SW Download
link. The
SW Download
pane appears.
Summary of Contents for RUGGEDCOM WiN5100
Page 2: ...RUGGEDCOM WiN5100 WiN5200 User Guide ii ...
Page 8: ...RUGGEDCOM WiN5100 WiN5200 User Guide FCC Statement And Cautions viii ...
Page 26: ...RUGGEDCOM WiN5100 WiN5200 User Guide Chapter 2 Product Description LED Indicators 18 ...
Page 28: ...RUGGEDCOM WiN5100 WiN5200 User Guide Chapter 3 Mounting Wall Mounting 20 ...
Page 106: ...RUGGEDCOM WiN5100 WiN5200 User Guide Appendix A WiN5100 WiN5200 Specifications 98 ...
Page 114: ...RUGGEDCOM WiN5100 WiN5200 User Guide Appendix D RUGGEDCOM CPE Warranty 106 ...