Page 78
SITRANS LG200 – INSTRUCTION MANUAL
7ML19985KA02
Tr
oubl
esho
ot
ing
TrimReqd
Factory set Loop values are
defaults; loop output may
be inaccurate
Consult factory
Cal Reqd
Factory set default calibra-
tion parameters are in use;
level reading may be inac-
curate
Consult factory
SlopeErr
Ramp circuit generating
improper voltage
Consult factory
LoopFail
Loop current differs from
expected value
Consult factory
No Ramp
No End-of-Ramp signal
detected
Consult factory
DfltParm
Internal non-volatile
parameters have been
defaulted
Consult factory
EE Fail
EEPROM error allowing
watch-dog timer to expire
Consult factory
CPU Fail
A-D converter time out
allowing watch-dog timer
to expire
Consult factory
SfwrFail
A fatal software error
allowing watch-dog timer
to expire
Consult factory
Display message
Action
Comment
Summary of Contents for 7ML1301-1
Page 1: ...Instruction Manual February 2009 LG200 sitrans ...
Page 10: ...Page 6 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 SITRANS LG200 Notes ...
Page 59: ...7ML19985KA02 SITRANS LG200 INSTRUCTION MANUAL Page 55 SIMATIC PDM ...
Page 60: ...Page 56 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 SIMATIC PDM Notes ...
Page 96: ...Page 92 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 Hazardous Installation ...