7ML19985KA02
SITRANS LG200 – INSTRUCTION MANUAL
Page 13
Specificat
io
ns
Transition
zone:
Bottom
25 mm (1”) @ dk
≥
10
150 mm (6”) @ dk
= 1.4
25 mm (1”) @ dk =
80
25 mm (1”) @ dk
>10
25 mm (1”) @ dk
>10
25 mm (1”) @ dk >10
Process
temperature
maximum
+343 °C @
165 bar g
(+650 °F @
2400 psi g)
(saturated
steam)
+200 °C @
18 bar g
(+400 °F @
270 psi g)
+150 °C @
27 bar g (+300 °F
@ 400 psi g)
+316 °C @
165 bar g
(+605 °F
@ 2400 psi g)
+150 °C @ 27 bar g
(+300 °F @ 400 psi g)
Process
temperature
minimum
-40 °C @
207 bar g
(-40 °F @
3000 psi g)
-40 °C @ 70 bar g
(-40 °F @
1000 psi g)
-40 °C @ 70 bar g
(-40 °F @
1000 psi g)
-40 °C @ 70 bar g
(-40 °F @
1000 psi g)
-40 °C @ 50 bar g
(-40 °F @ 750 psi g)
Process
pressure
maximum
165 bar g @
+343 °C
(2400 psi g @
+650 °F)
70 bar g @ +20 °C
(1000 psi g @
+70°F)
70 bar g @
+20 °C
(1000 psi g @
+70 °F)
207 bar g @
+20 °C
(3000 psi g @
+70 °F)
70 bar g @ +20 °C
(1000 psi g @ +70 °F)
Process
pressure
minimum/
vacuum
service
Yes, not
hermetic
Yes, not hermetic Not suitable
Not suitable
Not suitable
Dielectric
range
10 to 100
Upper liquid layer
1.4 to 5
Interface liquid
layer 15 to 100
1.9 to 100
1
1.9 to 100
1
1.9 to 100
1
Maximum
viscosity
Standard
Enlarged
500 cP
N/A
500 cP
1500 cP
10000 cP (consult factory if severe agitation/turbulence)
Coating/
buildup
No
No
Yes, maximum error 10% of coated length;% error related to
dielectric of media, thickness of coating and coated probe
length above media
Foam
No
No
Yes
Yes
Yes
Corrosives
Yes
Yes
Yes
Yes
Yes
Sanitary
No
No
No
No
No
Overfill
Yes
Yes
No
No
No
1.
With dK of 1.9 to 10, the device must be mounted between 50 and 150 mm (2 to 6”) of metal tank
wall or in chamber/bridle
2.
See O-ring Selection Guide for guidance
Summary of Contents for 7ML1301-1
Page 1: ...Instruction Manual February 2009 LG200 sitrans ...
Page 10: ...Page 6 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 SITRANS LG200 Notes ...