Installation Instructions
Recommended equipment and tools
•
Open-end wrenches or adjustable wrench to fit the process connection size and
type. Coaxial probe 1½” (38 mm), twin rod probe 1-7/8” (47 mm), transmitter 1½”
(38 mm). A torque wrench is preferred.
•
Flat-blade screwdriver
•
Digital multimeter or digital volt/ammeter
•
24 V DC power supply, 23 mA
General installation instructions
Before installation, ensure that:
•
Probe Type, Process Connection Type and Length are known (examine nameplate
and
Probe specifications
on page 10 for information needed)
•
Probe has adequate room for installation and has unobstructed entry to the bottom
of the vessel. The Model 7ML1301-2 (High Temp./High Pressure) probe, Model
7ML1301-3 (High Pressure) probe, Model 7ML1301-4 (Overfill) probe, Model
7ML1301-5 (Steam) probe and Model 7ML1301-6 (Interface) probe require added
clearance.
•
Process temperature, pressure, dielectric, and viscosity are within the probe
specifications for the installation.
•
Handle Model 7ML1301-2 (High Temperature/High Pressure) probes with extra care.
WARNING: Do not disassemble probe when in service and under
pressure.
High Level or Overfill Applications:
• The Model 7ML1301-2, 7ML1301-4 or 7ML1301-6 overfill probes should be used for
Shutdown/Overfill applications.
• All other Guided Wave Radar probes should be installed so the maximum overfill
level is a minimum of 150 mm (6") below the process connection. A nozzle can raise
the probe to the appropriate level. Consult factory to ensure proper installation.
CAUTION: Do not place insulating material around any part of the SITRANS
LG200 transmitter including the probe flange as this may cause excessive
heat buildup.
Note:
Do not use sealing compound
or
TFE tape on probe connection to transmitter as
this connection is sealed with a Viton® O-ring.
Summary of Contents for 7ML1301-1
Page 1: ...Instruction Manual February 2009 LG200 sitrans ...
Page 10: ...Page 6 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 SITRANS LG200 Notes ...
Page 59: ...7ML19985KA02 SITRANS LG200 INSTRUCTION MANUAL Page 55 SIMATIC PDM ...
Page 60: ...Page 56 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 SIMATIC PDM Notes ...
Page 96: ...Page 92 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 Hazardous Installation ...