Measurement Type (MeasType)
Select measurement type. (User password)
Level Units (LVL
Units)
Select level units. (User password)
Probe Length (Probe Ln)
Probe length is type dependant and is printed on the nameplate and order information.
(User password). Please consult Probe specifications on page 10 for minimum and
maximum lengths of specific probe models.
Level Offset (Lvl Ofst)
Level Offset is the distance from the probe tip to the desired zero level point. Enter
desired reading when probe is dry. (User password)
Offset Description
The parameter referred to as Lvl Ofst in the SITRANS LG200 menu is the desired level
reading when liquid surface is at the end of the probe. The LG200 transmitter is shipped
from the factory with Lvl Ofst set to 0. With this configuration, all measurements are
referenced from the bottom of the probe. See Example 1.
Example 1 (Lvl Ofst = 0):
Values
Lvl Only (Default)
Lvl&Vol
Intrface [7ML1301-6 (7xT-x) only]
Ifc&Vol [7ML1301-6 (7xT-x) only]
Values
cm
inches (Default)
feet
meters
Values
Probe Ln xxx.x (Default: 120.0 in)
Values
Range: -61 to 762 cm (-24 to 300 in) (Default: 0 in)
Note:
Device firmware will allow a negative value up to the probe length to be
accepted.
Summary of Contents for 7ML1301-1
Page 1: ...Instruction Manual February 2009 LG200 sitrans ...
Page 10: ...Page 6 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 SITRANS LG200 Notes ...
Page 59: ...7ML19985KA02 SITRANS LG200 INSTRUCTION MANUAL Page 55 SIMATIC PDM ...
Page 60: ...Page 56 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 SIMATIC PDM Notes ...
Page 96: ...Page 92 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 Hazardous Installation ...