Page 70
SITRANS LG200 – INSTRUCTION MANUAL
7ML19985KA02
Pa
ra
m
e
te
r R
e
fe
re
n
c
e
Scale Offset (Scl Ofst)
(factory authorized personnel only)
Default: 0. Calibration parameter. Expressed in mm, typically between 0 and 50, but will
vary with mounting process connection and probe type; factory password required.
Adjusting Trim Level is equivalent in opposite direction and requires a user password.
Negative Amplitude (Neg Ampl)
(factory authorized personnel only)
Default: 36. Diagnostic parameter. Controls the threshold setting for detection of the
negative signal for Fixed Threshold mode, and is where the echo is selected for
measurement. Changing probe model or dielectric range will adjust negative amplitude
appropriately; Superuser password required.
Interface Amplitude (Ifc Ampl)
(factory authorized personnel only)
Applicable only when Ifc, Ifc&Vol selected. Default: 36. Diagnostic parameter. Controls
the threshold setting for detection of the negative level signal corresponding to the
interface level in Fixed Threshold mode; Superuser password required.
Positive Amplitude (Pos Ampl)
(factory authorized personnel only)
Default: 60. Diagnostic parameter. Controls the threshold setting for detection of the
positive end of probe signals. Changing probe model or dielectric range will adjust
amplitude correctly; Superuser password required.
Signal (Signal)
(factory authorized personnel only)
Indication of level signal amplitude with respect to the CFD (Constant Fraction
Discriminator) threshold position
Compensate (Compsate)
(factory authorized personnel only)
1
Default: None. Select from None, Manual, or Auto; Superuser password required.
Derating Function (Lvl only)
(factory authorized personnel only)
1
Compensate = Auto. Velocity Derating factor for Model 7ML1301-5 Steam probe
Target Amplitude (Lvl only)
(factory authorized personnel only)
1
Compensate = Auto. Indication of steam reference target amplitude
Target Ticks (Lvl only)
(factory authorized personnel only)
1
Compensate = Auto. Measured time of flight from reference point to steam reference
target
Target Calibration (Lvl only)
(factory authorized personnel only)
1
Default: 1000. Compensate = Auto. Calibrated time of flight from reference point to target
in room temperature air.
1.
For Steam Probe model [7ML1301-5 (7xS-x)] only. This parameter is dependent on value of
Compensate parameter.
Summary of Contents for 7ML1301-1
Page 1: ...Instruction Manual February 2009 LG200 sitrans ...
Page 10: ...Page 6 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 SITRANS LG200 Notes ...
Page 59: ...7ML19985KA02 SITRANS LG200 INSTRUCTION MANUAL Page 55 SIMATIC PDM ...
Page 60: ...Page 56 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 SIMATIC PDM Notes ...
Page 96: ...Page 92 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 Hazardous Installation ...