Page 8
SITRANS LG200 – INSTRUCTION MANUAL
7ML19985KA02
Specificat
ions
• LCD temperature range
-20 to +70 °C (-5 to +160 °F)
• humidity
0 to 99%, non-condensing
Measurement accuracy
• linearity
1
<12.7 mm (0.5")
• measured error
Upper layer: ± 25.4 mm (1")
Interface layer: ± 25.4 mm (1") (clean distinct interface
required)
• resolution
±2.5 mm (0.1")
• repeatability
<12.7 mm (0.
5
")
• hysteresis
<12.7 mm (0.5")
Update time
< 1 second
Influence of amb. temperature +0.02% of probe length/°C
Upper layer dielectric
1.4 to 5.0
Interface layer dielectric
>15
Electromagnetic compatibility
2
Meets CE requirements (EN 61000-6-2/2001,
61000-6-4/2001)
Input
• measured variable
level, determined by time-of-flight of guided radar pulse
from transmitter to product surface and back
• zero and span
15 cm to 22.86 m (6" to 75 ft)
• user interface
3 button menu-driven data entry and system security
• digital communication
HART Version 5.x compatible
Output
• mA
Analog: 4 to 20 mA with HART digital signal
• range
Analog: 3.8 to 20.5 mA usable
• resolution
Analog: 0.01 mA
Digital: 2.5 mm (0.1")
• start-up current
4 mA
1.
Top 610 mm (24") of Model 7ML1302-1 probe: 30 mm (1.2"). Specification for top 1.22 m (48") will be
application dependent.
2.
Single and Twin Rod probe versions should only be used in metallic vessels or stilling wells for
compliance with CE regulations (where applicable)
Summary of Contents for 7ML1301-1
Page 1: ...Instruction Manual February 2009 LG200 sitrans ...
Page 10: ...Page 6 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 SITRANS LG200 Notes ...
Page 59: ...7ML19985KA02 SITRANS LG200 INSTRUCTION MANUAL Page 55 SIMATIC PDM ...
Page 60: ...Page 56 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 SIMATIC PDM Notes ...
Page 96: ...Page 92 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 Hazardous Installation ...