Parameter Reference
The following parameter listing explains the SITRANS LG200 parameter menus. Each
parameter is marked if it applies specific application types (Level, Volume, Interface/
Level, Interface/Volume).
The parameters are in the order they would appear if the arrow keys were used to scroll
through the menu.
To reset SITRANS LG200 to factory defaults, set each parameter to the default parameter
settings shown in user parameters below or listed in
Appendix A: Alphabetical Parameter
List
on page 72.
Display loop
Run Mode Display Options
*Status*
If you choose *Status*, the LG200 display will show Status, Level , % Output, and Loop
(and/or Volume, and/or Interface/Level, and/or Interface/Volume) values cycling every
two seconds.
Level
Displays level value in selected units.
Values (View only)
*Status*
*Level* or *Volume* or *IfcLvl* or *IfcVol*
*% Out*
*Loop*
Level: Measures
level only in
selected level
units
Volume: Measures
volume only in
selected volume
units
Interface/Level
(Ifc/Level):
Measures
upper level and
interface level
Interface/Volume
(Ifc/Vol): Measures
interface level and
interface volume
Values (View only)
Level xxx.x (in, cm, ft, m)
Summary of Contents for 7ML1301-1
Page 1: ...Instruction Manual February 2009 LG200 sitrans ...
Page 10: ...Page 6 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 SITRANS LG200 Notes ...
Page 59: ...7ML19985KA02 SITRANS LG200 INSTRUCTION MANUAL Page 55 SIMATIC PDM ...
Page 60: ...Page 56 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 SIMATIC PDM Notes ...
Page 96: ...Page 92 SITRANS LG200 INSTRUCTION MANUAL 7ML19985KA02 Hazardous Installation ...