112
O P E R A T I N G I N S T R U C T I O N S | safeRS3
8027489/2022-03-01 | SICK
Subject to change without notice
9 TECHNICAL REFERENCES
Parameter
Min
Max
Default value
Configuration
Number of installed sensors
1
6
1
Plane
Dim. X: 1000 mm
Dim. Y: 1000 mm
Dim. X: 65000
mm
Dim. Y: 65000
mm
Dim. X: 8000 mm
Dim. Y: 6000 mm
Position (for each sensor)
X: 0 mm
Y: 0 mm
X: 65000 mm
Y: 65000 mm
Default position of
sensor #1:
X: 1000 mm
Y: 1000 mm
Rotation (for each sensor)
0°
359°
0°
Inclination (for each sensor)
-90°
90°
0°
Sensor installation height (for each
sensor)
0 mm
10000 mm
0 mm
Detection Distance 1 (for each
sensor)
0 mm
5000 mm
1000 mm
Detection Distance 2, 3 and 4 (for
each sensor)
0 mm
5000 mm
Note
: the sum
of all the
detection
distances (for
each sensor)
must not
exceed 5000
mm.
0 mm
Angular coverage
10°
100°
100°
Safety working mode (for each
protective field of each sensor)
Both (default), Always access
detection, Always restart prevention
Both (default)
Static object detection (for each
protective field of each sensor)
Enabled, Disabled
Disabled
Restart timeout (for each protective
field of each sensor)
100 ms
60000 ms
4000 ms
T
OFF
100 ms
60000 ms
100 ms
Settings > Sensors
Protective field dependency
Enabled, Disabled
Enabled
Anti-masking
Disabled, Low, Medium, High
High
Anti-masking distance
0 mm
1000 mm
1000 mm
Anti-rotation around axes
Disabled, Enabled
Enabled
Anti-rotation around axes - Enable
specific axes - Tilt
Disabled, Enabled
Enabled
Anti-rotation around axes - Enable
specific axes -Roll
Disabled, Enabled
Enabled
Anti-rotation around axes - Enable
specific axes - Pan
Disabled, Enabled
Enabled