8.6.2
CAN errors (CAN ERROR)
Error
Meaning
TIMEOUT
Timeout on message to sensor/control
CROSS CHECK
Two redundant messages do not coincide
SEQUENCE
NUMBER
Message with sequence number different from the expected number
CRC CHECK
Packet control code does not match
COMMUNICATION
LOST
Impossible to communicate with the sensor
PROTOCOL ERROR
Control and sensors have different and incompatible firmware versions
POLLING TIMEOUT
Timeout on data polling
8.7
Cleaning and spare parts
8.7.1
Cleaning
Keep the sensor clean and free of any work residues to prevent masking and/or poor
functioning of the system.
8.7.2
Spare parts
Part
Product code
Sensor
safeRS3 Sensor
Control
safeRS3 Control PROFINET, safeRS3 Control
I/O
8 MAINTENANCE AND TROUBLESHOOTING
8027489/2022-03-01 | SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S | safeRS3
95