5.2.2
Protective field parameters
These are the programmable parameters for each protective field:
l
angular coverage
l
detection distance
l
safety working mode (
Both (default)
,
Always access detection
or
Always restart
prevention
) (see
Safety working modes and safety functions on page 40
)
l
restart timeout
5.2.3
Angular coverage
The angular coverage has a fixed value in a range from 10° to 100°.
The angular coverage of the protective field must be wider than, or equal to, the angular
coverage of the following protective fields.
5.2.4
Detection distance
The detection distance of the first protective field must start from the sensor. The
detection distance of one field starts where the one of the previous field ends.
5 FUNCTIONING PRINCIPLES
8027489/2022-03-01 | SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S | safeRS3
37