8 MAINTENANCE AND TROUBLESHOOTING
Error
Meaning
OSSD 1 NO LOAD
No load detected on MOS output 1
OSSD 2 NO LOAD
No load detected on MOS output 2
OSSD 3 NO LOAD
No load detected on MOS output 3
OSSD 4 NO LOAD
No load detected on MOS output 4
OSSD 1-2 CROSS
CHECK
Short-circuit error between MOS output 1 and 2
OSSD 1-3 CROSS
CHECK
Short-circuit error between MOS output 1 and 3
OSSD 1-4 CROSS
CHECK
Short-circuit error between MOS output 1 and 4
OSSD 2-3 CROSS
CHECK
Short-circuit error between MOS output 2 and 3
OSSD 2-4 CROSS
CHECK
Short-circuit error between MOS output 2 and 4
OSSD 3-4 CROSS
CHECK
Short-circuit error between MOS output 3 and 4
8.4.7
Flash errors (FLASH ERROR)
A flash error represents an error on the external flash.
8.4.8
Dynamic configuration error (DYNAMIC CONFIGURATION ERROR)
A dynamic configuration error indicates an invalid dynamic configuration ID.
8.4.9
Internal communication error (INTERNAL COMMUNICATION ERROR)
Indicates that there is an internal communication error.
8.4.10
Input redundancy error (INPUT REDUNDANCY ERROR)
Error
Meaning
INPUT 1
Error in the redundancy on Input 1
INPUT 2
Error in the redundancy on Input 2
8.4.11
Fieldbus error (FIELDBUS ERROR)
At least, one of the inputs and outputs has been configured as “Fieldbus controlled”,
but the fieldbus communication is not established or not valid.
Error
Meaning
NOT VALID COMMUNICATION
Error on the Fieldbus