4.4
safeRS3 Designer application
4.4.1
Functions
The application permits the following main functions to be performed:
l
Configure the system.
l
Create the configuration report.
l
Check system functioning.
l
Download system log.
4.4.2
safeRS3 Designer application usage
To use the application, the control must be connected to a computer with a data micro-
USB cable or, if the Ethernet port is available, an Ethernet cable. The USB cable allows
to configure the system locally, whereas the Ethernet cable allows to do it remotely.
The Ethernet communication between the control and the safeRS3 Designer application
is secured by the most advanced security protocols (TLS).
4.4.3
Access
The application can be downloaded free of charge at
www.sick.com
.
Some functions are password protected. The admin password can be set through the
application and then saved on the control. The available functions according to access
type are presented as follows:
Available functions
Access type
l
Display the system status (
Dashboard
)
l
Display the sensors configuration (
Configuration
)
l
Restore factory default settings, if not using Ethernet connection
(
Settings
>
General
)
l
Back up the configuration (
Settings
>
General
)
without password
l
Synchronize more controls (
Settings
> Multi-control synchronization)
l
Validate the system (
Validation
)
l
Restore factory default settings, if using Ethernet connection (
Settings
>
General
)
l
Download the system log and display reports (
Settings
>
Activity
History
)
l
Check the current checksum for each dynamic configuration (Settings >
Configuration checksum
)
l
Configure the system (
Configuration
)
l
Load a configuration (
Settings
>
General
)
l
Change the admin password (
Settings
>
Account
)
l
Show and change the network parameters - if available (
Settings
>
Network Parameters
)
l
Show and change the Modbus parameters - if available (
Settings
>
Modbus Parameters
)
l
Show and change the Fieldbus parameters - if available (
Settings
>
Fieldbus Parameters
)
with password
4 GET TO KNOW SAFERS3
8027489/2022-03-01 | SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S | safeRS3
29