Electrical installation
5.3.3
Inserting the cloning module
Insert the cloning module into the slot on the CDB650 connection module.
NOTE
Disconnecting the connection module
Mounting may only take place when the power to the connection module has been
disconnected.
1. Undo the screws on the cover and remove it from the connection module.
2. Set switch
S1
(Power) to OFF to ensure that the connection module is isolated from
the supply voltage.
3. In the connection module, set switch
S4
(CMC) to the bottom position to operate the
CMC600.
4. Insert the cloning module into the connection module at the designated slot.
The housing nose of the CMC600 then automatically interlocks the
S4
(CMC) switch.
Fig. 25: Inserting the cloning module in the connection module
5. Set the write protection switch of the CMC600 to the top position (OFF) if you wish
to describe the CMC600 memory.
Fig. 26: Write protection switch in the cloning module
6. Set the
S1
(Power) switch back to ON.