Commissioning RFID Access
Management
3. When you click
OK
or
Yes
to confirm the new IP address, the configuration PC will
address the RFID interrogator correctly via its IP address.
4. Proceed as follows for the other RFID interrogators.
The RFID interrogator uses two ports (like all SICK devices). Ports are part of the
network address and can be used to establish various connections between the
devices.
Port
2112
is freely configurable but port
2111
is a fixed port for outputting data.
It is used for device configuration.
5. Select fixed port
2111
for each device. Tick the corresponding checkboxes and click
Next
to confirm.
Note the IP addresses. They will be used later on when creating the access points in RFID
Access Management.
Note
Note
IP addresses