Operating instructions
Chapter
3
RFID Access Management
8018582/2015-11-03
Operating instructions| SICK
27
Subject to change without notice
System description
3.3.4
CMC600 cloning module
The cloning module has the following configuration switches and status indicators:
Fig. 15: Status indicators on the cloning module
No.
Meaning
1
Switch for network address
2
Switch for operating mode
3
Write protection switch
4
Monitoring LEDs
Tab. 8: Configuration switches and status indicators in the cloning module
Behavior of the yellow monitoring LED
Behavior
Meaning
Flashing slowly
The cloning module has launched and is waiting for commands
from the RFID interrogator.
Flashing rapidly
The cloning module was switched to transparent (mode 0).
The RFID interrogator cannot access the cloning module.
Tab. 9: Yellow monitoring LED in the cloning module
Behavior of the green monitoring LED
Behavior
Meaning
Flashing
(briefly on, mainly off)
The RFID interrogator is importing parameter values from the
cloning module.
Flashing
(briefly on, mainly off)
The RFID interrogator is copying parameter values to the
cloning module.
Permanently on
The cloning module is operational. The RFID interrogator has
successfully accessed the cloning module.
Tab. 10: Green monitoring LED in the cloning module