2 SPECIFICATIONS
2.4 Performance Specifications
31
2
Test outputs of an FX5-SF-MU4T5
*1 A cross-circuit detection is performed only in the module.
*2 All the output current in a system is limited. Observe the following limit values.
Supply current for all sensors connected to an FX5-SF-MU4T5 (T0/T1) and FX5-SF-8DI4 (T0 to T7): I < 600 mA
Safety outputs of an FX5-SF-MU4T5
*1 A cross-circuit detection is performed only in the module.
*2 A response time without any sensors. When sensors are connected, the data of the connected sensors is applied and the minimum
switch-off time is extended.
Item
Specification
Number of outputs
2 points
Output method
Source output, short-circuit protection, cross-circuit detection
Output voltage
16 VDC to 30 VDC
Output current
120 mA
Test cycle (T0 and T1)
Program 1, 2, 4, 5, 6, and 9
40 ms
Program 3.2
T0 = 400 ms
T1 = 40 ms
Item
Specification
Number of outputs
4 points
Output method
Source output, short-circuit protection, cross-circuit detection
Output voltage
18.4 VDC to 30.0 VDC
Switching current
2.0A( T
A
≤
45
)
1.5A( T
A
≤
55
)
Total current I
sum
4.0A( T
A
≤
45
)
3.0A( T
A
≤
55
)
Leak current (in the switch OFF status)
1 mA or less
Indication of output operation
LED lights when an output is ON.
(I0/I1)
Program 1, 2, 4, 5, 6, and 9
29 ms
Program 3.1, 7, and 8
9 ms
Program 3.2
81 ms/29 ms
(I2/I3)
Program 4, 5, and 6
29 ms
Program 1, 2, 3, 7, 8, and 9
9 ms
Response time (XS0)
9 ms
Off delay time
0 / 0.5 / 1 /1.5 / 2 / 2.5 / 3 / 3.5 / 4 / 5 s
@
@
@
@
Summary of Contents for MITSUBISHI ELECTRIC MELSEC iQ-F FX5
Page 2: ......
Page 29: ...1 OVERVIEW 27 1 MEMO ...
Page 40: ...38 3 PROCEDURES BEFORE OPERATION MEMO ...
Page 90: ...88 5 SYSTEM CONFIGURATION MEMO ...
Page 112: ...110 7 PARAMETER SETTINGS 7 1 Refresh Setting MEMO ...
Page 117: ...9 COMMISSIONING 9 2 Considerations for Inspection 115 9 MEMO ...
Page 171: ...I 169 MEMO ...
Page 175: ......