4 FUNCTIONS
4.5 AND link
73
4
Page 57 Details of the program 5 for FX5-SF-MU4T5s
Page 59 Details of the program 6 for FX5-SF-MU4T5s
Page 61 Details of the program 7 for FX5-SF-MU4T5s
Page 65 Details of the program 9 for FX5-SF-MU4T5s
■
For FX5-SF-MU4T5 and FX5-SF-8DI4
Set the FUNCTION rotary switch of an FX5-SF-MU4T5 as necessary.
Set a rotary switch to any one of 1 to 6 depending on the sensor connected to the FX5-SF-8DI4.
Sensors that can be connected to an FX5-SF-8DI4 are as follows.
: Connectable,
: Not connectable
Operation
■
For FX5-SF-MU4T5
Connect I0/I1 and I2/I3 of an FX5-SF-MU4T5 using AND logic.
■
For FX5-SF-MU4T5 and FX5-SF-8DI4
Connect a logic path of an FX5-SF-MU4T5 to an input of the FX5-SF-8DI4 using AND logic.
Precautions
To prevent the AND logic to always be '0', connect unused input terminal to a plus terminal.
FX5-SF-8DI4
(Program)
Inputs and sensors
Description
Input (I0 to
I3)
Input (I4 to
I7)
1
•
: Potential free contact
•
: Emergency stop button
•
: Safety door switch
Single-channel N/C contact
: Single-beam photoelectric safety
sensor
Single-channel N/C contact
2
: Potential free contact
Dual-channel equivalent N/C contact (with
cross-circuit detection)
•
: Emergency stop button
•
: Safety door switch
Dual-channel equivalent N/C contact (with
cross-circuit detection)
Safety mat
Pressure sensitive mat (four-wire system)
: Non-contact safety switch
Dual-channel equivalent N/C contact
: Single-beam photoelectric safety
sensor
Dual-channel equivalent N/C contact (with
cross-circuit detection)
3
: Potential free contact
Dual-channel equivalent N/C contact (with
cross-circuit detection)
•
: Emergency stop button
•
: Safety door switch
Dual-channel equivalent N/C contact (with
cross-circuit detection)
: Non-contact safety switch
Dual-channel equivalent N/C contact
: Single-beam photoelectric safety
sensor
Dual-channel equivalent N/C contact (with
cross-circuit detection)
4
: Potential free contact
Dual-channel complementary N/C / N/O
contact (with cross-circuit detection)
5
: Non-contact safety switch
Dual-channel complementary N/C / N/O
contact (with cross-circuit detection and
synchronous time monitoring)
6
•
: Potential free contact
•
: Emergency stop button
•
: Safety door switch
Single-channel N/C contact
•
: Potential free contact
•
: Emergency stop button
•
: Safety door switch
Dual-channel equivalent N/C contact
: Electro-sensitive protective
equipment (ESPE)
Electro-sensitive protective equipment
(ESPE) with semiconductor output
: Inductive switch
Sensor with semiconductor output (OSSD
output)
: Single-beam photoelectric safety
sensor
Dual-channel equivalent N/C contact
Summary of Contents for MITSUBISHI ELECTRIC MELSEC iQ-F FX5
Page 2: ......
Page 29: ...1 OVERVIEW 27 1 MEMO ...
Page 40: ...38 3 PROCEDURES BEFORE OPERATION MEMO ...
Page 90: ...88 5 SYSTEM CONFIGURATION MEMO ...
Page 112: ...110 7 PARAMETER SETTINGS 7 1 Refresh Setting MEMO ...
Page 117: ...9 COMMISSIONING 9 2 Considerations for Inspection 115 9 MEMO ...
Page 171: ...I 169 MEMO ...
Page 175: ......