4 FUNCTIONS
4.6 OR link
75
4
■
For FX5-SF-MU4T5 and FX5-SF-8DI4
Set the FUNCTION rotary switch of an FX5-SF-MU4T5 as necessary.
Set the rotary switch of an FX5-SF-8DI4 to '7'.
Sensors that can be connected to an FX5-SF-8DI4 are as follows.
: Connectable,
: Not connectable
Operation
■
For FX5-SF-MU4T5
Connect I0/I1 and I2/I3 of an FX5-SF-MU4T5 using OR logic.
■
For FX5-SF-MU4T5 and FX5-SF-8DI4
Connect the inputs of an FX5-SF-MU4T5 and the inputs of the OR function
*1
of an FX5-SF-8DI4 using OR logic.
*1 When the INPUT A rotary switch of an FX5-SF-8DI4 is set to '7', I0/I1 and I2/I3 will be the input of the OR function. When the INPUT B
rotary switch of an FX5-SF-8DI4 is set to '7', I4/I5 and I6/I7 will be the input of the OR function.
Precautions
• The output of the FX5-SF-MU4T5 is kept ON while the OR function is enabled and any of the safety inputs are turned ON.
• During the OR function is active, make sure that there is no danger to people or parts of the machine by using other
protective equipments. For example, when using the OR function for a setup mode, make sure that the protective
equipments, such as a safety setup mode of a machine, are forcibly enabled.
FX5-SF-8DI4
(Program)
Inputs and sensors
Description
Input (I0 to
I3)
Input (I4 to
I7)
7
•
: Potential free contact
•
: Emergency stop button
•
: Safety door switch
Single-channel N/C contact
•
: Potential free contact
•
: Emergency stop button
•
: Safety door switch
Dual-channel equivalent N/C contact
: Electro-sensitive protective
equipment (ESPE)
Electro-sensitive protective equipment
(ESPE) with semiconductor output
: Inductive switch
Sensor with semiconductor output (OSSD
output)
: Single-beam photoelectric safety
sensor
Dual-channel equivalent N/C contact
Summary of Contents for MITSUBISHI ELECTRIC MELSEC iQ-F FX5
Page 2: ......
Page 29: ...1 OVERVIEW 27 1 MEMO ...
Page 40: ...38 3 PROCEDURES BEFORE OPERATION MEMO ...
Page 90: ...88 5 SYSTEM CONFIGURATION MEMO ...
Page 112: ...110 7 PARAMETER SETTINGS 7 1 Refresh Setting MEMO ...
Page 117: ...9 COMMISSIONING 9 2 Considerations for Inspection 115 9 MEMO ...
Page 171: ...I 169 MEMO ...
Page 175: ......