Operating Instructions
Chapter
10
CLV 490 Bar Code Scanner
8 009 993/O824/20-12-2004
©
SICK AG · Division Auto Ident · Germany · All rights reserved
10-49
Appendix
10.6.5
Functions
The "CLV-Setup" program (from version V 4.0) features the following functions to carry out:
•
Uploading the default parameter set from the database of CLV-Setup
•
Automatic communication attempt with the CLV when the program is started
•
Automatic software compatibility check in the CLV
•
Uploading and displaying parameter set stored in the CLV
•
Changing the parameter/parameter values on the tabs
•
Downloading the changes to the parameter set in the CLV
•
Saving the changes to the parameter set as a configuration file "*.scl"
•
CLV Assistant for simplified parameterization (not for CLV 490)
•
Printing the configuration files
•
Exporting the configuration files in RTF format
•
Exporting the command strings contained in the profile bar codes in ASCII format
•
Printing the parameter set in the form of profile bar codes (not for CLV 490)
•
Online access to the CLV via a Terminal Emulator (select operating mode, start
operating functions, log file for communication between the CLV and CLV-Setup,
extended Terminal mode, e. g. for displaying CLV messages)
•
AutoBaud Detect for automatic communication setup with the CLV
•
Selecting the COM port of the PC for adapting the data transfer parameters
•
Monitoring the data communication of the CLV host interface
•
Selecting language setting
•
Selecting units of measure
•
Displaying the last 10 configuration files that were processed
•
Saving the CLV type that was selected last
•
Automatic storage confirmation prompt when changes are made to the configuration file
•
Wizards for individual functions
•
Clearing the optional CMC 400 parameter memory in the CDB/CDM Connection
Module
•
CLV 490 only: Aligment check to calculate the required setting for angles
•
CLV 490 only: Background analysis
•
CLV 490 only: I/O monitoring
•
Setting switches for starting the program (in the "CLVmain.ini" file)
•
Hot keys [F keys] for important functions (using the program without a mouse)
•
Starting program with SCL file as argument
•
Macro player for recording and playing a macro file
•
Context-sensitive help via the [F1] key
10.6.6
Hot keys
[F1]
Start "CLV-Setup Help“ online
[F2]
Open dialog box to execute device functions
[F3]
Upload complete set of parameters from CLV
[F4]
Download complete set of parameters to CLV
[F5]
Open configuration file
[F6]
Save configuration file