Electrical installation
See also the Fitting Instructions for the
"Cold-resistent cable no. 2 033 126/no. 2 033 127"
(order no. 8 010 971, German/English) used for CDB 420 respectively the Fitting Instruc-
tions for the
"Cold-resistent cable no. 2 030 065/no. 2 031 034"
(order no 8 010 972,
German/English) used for CDM 490.
b) Power supply via non-SICK Power pack
Connecting the CLV without connector cover:
1.
Connect the cable socket on cable no. 2 020 303 on the "Host/Term" connection and
screw it tightly into position.
2.
Connect the cable plug on the cable no. 2 020 264 to the "I/O" connection and screw
it tightly into position.
3.
Connect the power supply to the red wire (Pin 1, V
S
) and blue wire (Pin 5, GND) on cable
no. 2 020 303.
See also
Connecting the CLV with connector cover/connector cover with parameter memory:
1.
Connect the connector cover of the cable no. 2 020 981 or no. 2 021 267 to the
"Host/Term" and "I/O" connections on the CLV and secure it tightly.
2.
For the cable no. 2 020 981 connect the power supply to the red/pink wire (Pin 1, VS)
and the blue/grey-brown wire (Pin 5, GND) of cable 1. See also
.
For the cable no. 2 021 267 connect the power supply to the red wire (Pin 1, VS) and
the black wire (Pin 5, GND) of cable 2. See also
.
The CLV is connected to the supply voltage.