Appendix
5.
Connect the pulse photoelectric switch to the CDB 420 or CDM 490 connection mo-
dule
(see
Chapter 5.5.7 Connecting the "Sensor" switching input, Page 5-23
).
6.
Turn on the supply voltage to the CLV.
10.10.6 Parameterize the CLV with the "CLV-Setup" program
1.
Connect the PC to the CLV’s terminal interface (see
Chapter 5.5.6 Connecting the PC,
)
2.
Start Windows and the "CLV-Setup" program on the PC.
3.
Invoke the CLV 490’s default setting in the "CLV-Setup" program
(see
Chapter 6.1 Overview of steps for starting up the CLV, Page 6-1
).
4.
Parameterize the CLV with the help of
Chapter 6.4.4 Guide to parameterization menu,
and the tab cards by following the steps described.
5.
After completing parameter value alterations, download them to the CLV!
(see
chapter
Chapter 6.4.1 Configuring the CLV via the user interface of CLV-Setup,
).
1. Setting up the autofocus function (Part 1): R
EADING
C
ONFIGURATION
tab
¾
Set the following parameters:
– Scanning frequency:
800 Hz
– Start/stop ratio:
auto
– Trigger for focus position changeover:
autofocus
– Autofocus mode:
differential background
¾
Click on the
AUTOFOCUS
P
ARAMETERS
button.
The
AUTOFOCUS
P
ARAMETERS
tab then opens (
).
¾
Set the following parameters:
– Preference of focus distance:
Fix focus position:
1,200 mm
(47.3 in)
(approx. 100 mm (3.9 in) above the packet with the smallest height)
Fig. 10-45: Parameterization example: settings on the "Reading Configuration" tab