Chapter
10
Operating Instructions
CLV 490 Bar Code Scanner
10-76
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Appendix
10.13.3 Extensions for connection modules
Order No.
Type
Description
Design
1 023 850
CMC 400-101
Parameter memory (Connection Module Cloning) as plug-in module for
the
CDB 420
or
CDM 490
Connection Module.
Storage of parameter set for CLV 490 (from firmware V 3.50). Rotary
code switch for activating the net work mode for the CLV 490.
Operating temperature 0 to +40
°
C (+32 to +104
°
F), operating vol-
tage 10 to 30 V DC via CDB 420 or CDM 490, power consumption
0.5 W.
2 029 466
CDM 400
1)
Display module (Connection Display Module), 4 x 20 digits (LCD) with
keyboard in optional cover for the
CDM 490
Connection Module.
Representation of reading results, reading diagnosis data and mes-
sages from the CLV 490 (from firmware version V 3.50). Connection to
the CDM 490 via ribbon cable. Operating temperature 0 to +40
°
C
(+32 to +104
°
F), operating voltage 18 to 30 V DC via CDM 490,
power consumption 1 W.
Prerequisite: CMC 400-101 parameter memory for controlling the
display.
2 030 091
CMP 490
1)
Power Supply Module (Connection Module Power) in optional cover for
the
CDM 490
Connection Module.
Power supply for CLV 490 from an AC power line.
Input 100 to 250 V AC/50 to 60 Hz, output 24 V DC, max. 25 W
(short-circuit proof). Connection to the CDM 490 via ribbon cable.
Operating temperature 0 to +40
°
C (+32 to +104
°
F).
1 026 241
CMF 400-1001
Field bus gateway (Connection Module Fieldbus) as plug-in module for
the
CDM 490
Connection Module. For connecting one CLV 490 (from
firmware version V 3.50) to
Profibus-DP
(slave) via RS 232 data
interface.
With 9-pin D Sub socket on front panel for bus connection
(enclosure rating IP 20) and 5-core terminal strip for connecting 2 digi-
tal inputs and 2 digital outputs.
Connection to the CDM 490 via connector, operating temperature
0 to +40
°
C (+32 to +104
°
F), operating voltage 18 to 30 V DC via
CDM 490, power consumption 2 W.
1 026 643
CMF 400-1101
as CMF 400-1001, but with enclosure rating max. IP 65
–
1 026 242
CMF 400-2101
Field bus gateway (Connection Module Fieldbus) as plug-in module for
the
CDM 490
Connection Module. For connecting one CLV 490 (from
firmware version V 3.50) to
DeviceNet
(slave)
via RS 232 data inter-
face.
With shielded 5-pin M12 plug on front panel for bus connection
(enclosure rating max. IP 65) and 5-core terminal strip for connecting
2 digital inputs and 2 digital outputs.
Connection to the CDM 490 via connector, operating temperature
0 to +40
°
C (+32 to +104
°
F), operating voltage 18 to 30 V DC via
CDM 490, power consumption 2 W.
1 026 357
CMF 400-3101
Field bus gateway (Connection Module Fieldbus) as plug-in module for
the
CDM 490
Connection Module. For connecting one CLV 490 (from
firmware version V 3.50) to
Ethernet TCP/IP
via RS 232 data inter-
face.
With shielded 8-pin RJ-45 socket on front panel for bus connec-
tion (enclosure rating max. IP 65) and 5-core terminal strip for
connecting 2 digital inputs and 2 digital outputs.
Connection to the CDM 490 via connector, operating temperature
0 to +40
°
C (+32 to +104
°
F), operating voltage 18 to 30 V DC via
CDM 490, power consumption 3 W.
6 029 030
–
Profibus connector, IP 65, for CMF 400-1101
–
6 029 064
–
Ethernet patch cable, IP 65, 1 m (39.4 in), für CMF 400-3101
–
1) simultaneous operation together with the CMD 400 Display Module not possible
Table 10-13: Accessories: Extensions for connection modules