Chapter
10
Operating Instructions
CLV 490 Bar Code Scanner
10-66
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Appendix
– Angle gamma:
0 degrees
(Divergence of the scanner (reading windows) from the
perpendicular in the plane askew to the direction of feed)
¾
Set the following parameters in the C
OORDINATES
section:
– X coordinate: Measure
the distance from the pulse photoelectric switch to the
CLV’s reading window perpendicular!
(x x coordinate = the distance from the pulse photoelectric switch to the
CLV’s reading window perpendicular)
– Y coordinate:
300 mm (11.8 in)
(The middle of the CLV to the left edge of the con-
veyor belt in the direction of convoyer belt)
– Z coordinate:
1,400 mm
(55.2 in)
(Height of the CLV above the conveyor belt)
¾
Close the S
CANNER
P
OSITION
P
ARAMETERS
tab.
3. Set the reading pulse source: D
EVICE
C
ONFIGURATION
tab
¾
In the R
EADING
T
RIGGER
M
ODE
section click the option
Sensor Input (Active High)
.
¾
In the Output on Good read section click the option
End of label
.
¾
Close the tab.
Fig. 10-51: Parameterization example: Settings on the "Device Configuration" tab