2. Setting up the autofocus function (Part 2): D
EVICE
C
ONFIGURATION
tab
¾
Click on the S
CANNER
P
OSITION
P
ARAMETERS
button.
The S
CANNER
P
OSITION
P
ARAMETERS
tab then opens (
Set the following CLV position definition parameters regarding the movement level (
see also
¾
Set the following parameters in the A
NGLES
section:
– Angle alpha:
90 degrees
(Laser beam’s direction of deflection relative to the direc-
tion of convoyer belt.
– Angle beta:
10 degrees
(Laser beam’s angle of incidence relative to the perpendi-
cular in the area (Skew to the barcode), 10 degrees in the direction of feed)
Fig. 10-49: Parameterization example: Buttons on the "Device Configuration" tab
Fig. 10-50: Parameterization example: "Scanner Position Parameters" tab