Chapter
5
Operating Instructions
CLV 490 Bar Code Scanner
5-28
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Electrical installation
For connecting the switching outputs via the CDB 420 or CDM 490 Connection Module, see
the Operating Instructions for the
"CDB 420 Connection Module"
(no. 8 010 001, German/
English) respectively the Operating Instructions for the
"CDM 490 Connection Module"
(no. 8 010 005, German/English).
Tip
The output function, pulse duration (timer), and polarity of the signals can be changed on
the D
EVICE
C
ONFIGURATION
tab in the "CLV-Setup" program.
¾
Click the R
ESULT
O
UTPUTS
Parameter button.
Enter the values in the dialog box displayed.
Perform a download to the CLV.
Recommendation
¾
To check the switching functions using a high-impedance digital voltmeter, connect a
load to the outputs to prevent incorrect voltage values/switching statuses from being
displayed.