Electrical installation
5.5.9
Connecting the "Result 1" to "Result 4" switching outputs
The four switching outputs can be assigned different functions for outputting result statuses
independently of each other. If the assigned event occurs during the reading procedure, the
corresponding switching output becomes live at the end of the reading pulse for the select-
ed pulse duration. The pulse duration can be set individually for each output.
The "Read Result" LED is linked to the "Result 2" output and lights up in Reading mode for the
selected pulse duration and function of the result status display (default: Good Read, 100 ms).
shows the connections for the "Result 1" to "Result 4" switching outputs.
shows the pin assignment on the CLV.
contains the characteristic
data for these outputs. The four outputs have the same characteristic data.
¾
Connect the outputs as shown in
.
Note
In the
CDB 420
Connection Module only the signals of the "Result 1“ and "Result 2“ switch-
ing outputs can be connected using the terminal strips.
"
Note
If the "Device Ready" function is chosen, the CLV outputs a static pulse in Reading mode.
Fig. 5-7:
Connections of the "Result 1" to "Result 4" switching outputs
Output
"Result X"
CLV "I/O" connection
Pin Y
Result 1
Pin 4
Result 2
Pin 8
Result 3
Pin 10
Result 4
Pin 15
Table 5-30: Pin assignment for "Result 1" to "Result 4" switching outputs
GND
Result X
Fuse
Y
R
L
V
S
5
Logic
Temperature
sensor
V
S
= 18 to 30 V DC for CLV without heater,
24 V DC +20 %/–10 % for CLV with heater
Switching mode
PNP-switching with respect to the supply voltage V
S
Properties
The current in the event of a short-circuit is limited to 0.7 A
Function
assignment
(default)
"Result 1": Device Ready (static), polarity: not inverted
"Result 2": Good Read (100 ms), polarity: not inverted
"Result 3": No Ready (100 ms), polarity: not inverted
"Result 4": Match 1 (100 ms), polarity: not inverted
Electrical values
0 V
≤
V
O
≤
30 V
Guaranteed: V
O
≤
V
S
≤
1.3 V with I
0
≤
100 mA
I
0
≤
100 mA
Table 5-31: Characteristic data of the "Result 1" to "Result 4" switching outputs
Pulse duration
depending
on setting:
– 10 ms to 900 ms
– 100 ms to 9,900 ms
– 00: static
(to the end of next
reading pulse)
Pin assignment for
"
Result X
"