background image

Gryphon™ I GD4500

QUICK REFERENCE GUIDE

General Purpose Corded

Handheld Area Imager Bar Code Reader

Summary of Contents for Gryphon GD4500

Page 1: ...Gryphon I GD4500 QUICK REFERENCE GUIDE General Purpose Corded Handheld Area Imager Bar Code Reader...

Page 2: ...may be downloaded from the Data logic website www datalogic com If you visit our website and would like to make comments or suggestions about this or other Datalogic publica tions please let us know...

Page 3: ...attern 5 2D Matrix Symbol 5 Linear Bar 5 Relative Size and Location of Green Spot 6 Parts of the Reader 6 Selecting the Interface Type 6 Interface Selection 6 Configuring the Interface 7 Keyboard Inte...

Page 4: ...27 Warranty 28 Ergonomic Recommendations 29 Technical Support 29 Support Through the Website 29 Reseller Technical Support 29 Cleaning Procedure 30 Cleaning plastic surfaces 30 Common Cleaning Soluti...

Page 5: ...achine readable form only solely for End User s internal business purposes 1 2 End Users shall not distribute sublicense rent loan lease assign export re export resell ship or divert or cause to be ex...

Page 6: ...ermination shall be effective upon notice to the other party In the event that this Agreement terminates for any rea son End User s license to use the Software will immediately terminate and End User...

Page 7: ...other items not provided by Datalogic 7 Support End User may request support for Software from Datalogic at Datalogic s standard support fees and under Datalogic s standard support terms and conditio...

Page 8: ...which Open Source Software packages have source code provided or avail able 11 Notices All notices required or authorized under this Agreement shall be given in writing and shall be effective when rec...

Page 9: ...lidity interpretation and construction of the Agreement shall be governed by and construed in accordance with Laws of the Republic of Sin gapore Parties expressly disclaim the application of the Unite...

Page 10: ...customers with the very latest in Datalogic soft ware technology The only exception to this policy is when the buyer has a signed contract with Datalogic that clearly defines the terms and conditions...

Page 11: ...on I GD45XX is a powerful omni directional reader so the orientation of the symbol is not important Datalogic s exclusive pat ented Green Spot for good read feedback helps to improve productivity in n...

Page 12: ...d options for this feature HANDS FREE STAND HOLDER An accessory is available which holds the reader except those with integrated stand at a convenient angle allow ing hands free scanning of items It c...

Page 13: ...s below to connect and get your reader up and communicating with its host 1 Connect the Cable to the reader and the Host as shown below 2 Configure the Interface see page 8 3 Program the Reader starti...

Page 14: ...ke a paper clip and modify it as shown in the figure below Insert the end of the paper clip into the hole and press it to push on the clip that holds the connector As you apply pressure pull out the c...

Page 15: ...and decoding codes The reader is equipped with an inter nal Motionix motion sensing function which activates the aiming system on device motion The intelligent aim ing system indicates the field of vi...

Page 16: ...should be read closer to the unit Symbologies with larger bars or elements mil size should be read farther from the unit If the aiming system is centered and the entire bar code is within the aiming...

Page 17: ...y the reader and scan the appropriate bar code to select your system s correct interface type according to your application For interfaces other than those listed in this manual see the Gryphon I GD45...

Page 18: ...code to select the interface type for your system NOTE Unlike some other programming features and options interface selections require that you scan only one programming bar code label DO NOT scan an...

Page 19: ...lect RS232 STD RS 232 standard interface Select RS232 WN RS 232 Wincor Nixdorf Select RS 232 OPOS RS 232 for use with OPOS UPOS JavaPOS Select USB COM STDa USB Com to simulate RS 232 standard interfac...

Page 20: ...USB OEM USB OEM can be used for OPOS UPOS JavaPOS USB COMPOSITE Select USB Composite USB Composite Keyboard COM IBM46XX Select IBM46xx Port 9b USB FOR TERMINALS Select USB HID POS Select USB Toshiba...

Page 21: ...YBOARD Select KBD AT AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w standard key encoding Select KBD AT NK IBM AT PS2 with standard key encoding but without external keyboard Select KBD AT ALT AT PS 2...

Page 22: ...ey encoding AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Std Key Encoding Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard AT PS 2 25 286 30 286 50 50Z 60 70 80...

Page 23: ...he Interface Type QUICK REFERENCE GUIDE 13 COUNTRY MODE ENTER EXIT PROGRAMMING MODE Country Mode U S Country Mode Belgium Country Mode Croatia Country Mode Czech Republic Country Mode Denmark Country...

Page 24: ...rface Type 14 GRYPHON I GD4500 COUNTRY MODE CONTINUED Country Mode French Canadian Country Mode Germany Country Mode Hungary Country Mode Italy Country Mode Japanese 106 key Country Mode Lithuanian Co...

Page 25: ...Interface Type QUICK REFERENCE GUIDE 15 COUNTRY MODE CONTINUED Country Mode Poland Country Mode Portugal Country Mode Romania Country Mode Slovakia Country Mode Spain Country Mode Sweden Country Mode...

Page 26: ...scan of that single label to enact the change Other bar codes require the reader to be placed in Program ming Mode prior to scanning them Scan an ENTER EXIT bar code once to enter Programming Mode sca...

Page 27: ...wedge interface This only applies to alternate key encoding interfaces It does not apply to USB keyboard default value NOTE Factory defaults are based on the interface type Be sure your reader is conf...

Page 28: ...the format in which the reader sends character data This applies to keyboard wedge interfaces This does not apply when an alternate key encoding key board is selected default value CAPS LOCK STATE ENT...

Page 29: ...inator will remain on until the symbol is decoded As you read code symbols adjust the distance at which you are holding the reader Aiming System A number of options for customizing control of the Aimi...

Page 30: ...ime1 expires a label has been read the trigger is released Trigger Hold Multiple When the trigger is pulled scan ning starts and the product scans until the trigger is released or Scanning Active Time...

Page 31: ...reader is always ready for code reading Double Read Timeout1 prevents undesired multiple reads Object Detection The scanner looks for changes within its field of view The Aiming Pattern is always on...

Page 32: ...ting Modes 22 GRYPHON I GD4500 default value SCAN MODE CONTINUED Scan Mode Flashinga Scan Mode Always ON Stand Mode a Controlled by Flash On Time and Flash Off Time See the PRG to program these parame...

Page 33: ...acknowledged or transmitted to the host It is active only while the scanner is in Trigger Single mode If the scanner switches to a dif ferent Read Mode Pick Mode is automatically disabled default valu...

Page 34: ...ting Typical 400 mA 5V 200 mA 12V Standby Idle Typical 90 mA 5V 50 mA 12V Max Scan Rate 50 frames sec Reading Indicators Top and rear illumination Good Read Spot Beep Vibrator ENVIRONMENTAL CHARACTERI...

Page 35: ...38 0 cm 2 7 14 9 10 mil 2 2 58 0 cm 0 8 22 8 20 mil FOV lim 110 cm up to 43 3 3 mil 5 0 15 0 cm 2 0 5 9 5 mil 0 5 25 0 cm 0 2 9 8 10 mil 0 5 45 0 cm 0 2 17 7 EAN 13 7 5 mil 9 0 30 0 cm 3 5 11 8 13 mi...

Page 36: ...GBT GM4500 scanner is capable of decoding the following symbolo gies using multiple frames i e Multi Frame Decoding Data Matrix Inverse Data Matrix Data Matrix is configurable for the following parame...

Page 37: ...e LED blinks until enumeration with the host is completed Imager beeps four times at highest frequency and volume upon power up Good Read Upper green LED comes on for programmed time default LED behav...

Page 38: ...ode type Ensure reader is programmed to read the type of bar code scanned Refer to the PRG for more information Bar code label is unreadable Check the label to ensure it is not defaced Try to scan ano...

Page 39: ...whole unit consumable items 7 use of counterfeit or replacement parts that are neither manu factured nor approved by Datalogic for use in Datalogic manufactured Products 8 any damage or malfunctioning...

Page 40: ...ts website Log on to www datalogic com For quick access from the home page click on the search icon and type in the name of the product you re look ing for This allows you access to download Data Shee...

Page 41: ...ryphon device in good operating condition Common Cleaning Solutions The cleaners and disinfectants listed below are recom mended for use on Datalogic Disinfectant Ready Enclo sures WARNING Be sure to...

Page 42: ...Use the cloth to wipe down the surface of the unit Use cotton swabs lightly moistened to reach in cor ners and crevices 3 Use another clean dry cloth to remove any residue of the cleaning agent and en...

Page 43: ......

Page 44: ...s mitted in any form or by any means or for any purpose without the express written permission of Datalogic S p A and or its affiliates Datalogic and the Datalogic logo are registered trademarks of Da...

Reviews: