AFS60 AFM60 EIP WEB operating instructions
6
Instance
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
104
42
CNR_D value
43
CNR_D value (most significant byte)
44
Velocity format value (least significant byte)
45
Velocity format value
46
Velocity format value
47
Velocity format value (most significant byte)
48
Preset Value (least significant byte)
49
Preset Value
50
Preset Value
51
Preset Value (most significant byte)
1)
cw = clockwise
ccw = counterclockwise
2)
scf = scaling function
3)
raf = round axis functionality
The input assembly 104 contain the transmission of the serial number from the encoder.
This can be used in case of exchange the encoders, due to e. g. a fault / defect, to
compare wether it is a new device or the still existing because of different parameter
settings. If the encoders get the same IP-addressing, the unique serial number could
protect an start up with wrong parameters – and so prevent crashs or damages,
also save cost and time.
© SICK AG• Germany • All rights reserved
8018909/1EH9/2021-12-16
Subject to change without notice